The application of Haiwell S16S2R series PLC in testing the quality of ultrafiltration water treatment products...

One: Introduction to equipment design

In order to test the quality of ultrafiltration water treatment products, ultrafiltration testing equipment is specially designed and manufactured according to the testing methods and standards of the production workshop. The PLC of this equipment uses Haiwell’s S16S2R host and analog acquisition module S04AI, and the HMI is Kunlun Tongstate’s TPC7062TD.

Two: Haiwell PLC

S16S2R+S04AI

Application design of Haiwell S16S2R series PLC in testing the quality of ultrafiltration water treatment products

2. PLC electrical layout drawing

Application design of Haiwell S16S2R series PLC in testing the quality of ultrafiltration water treatment products

3. PLC assembly drawing

Application design of Haiwell S16S2R series PLC in testing the quality of ultrafiltration water treatment products

Three: PLC part of the program

Application design of Haiwell S16S2R series PLC in testing the quality of ultrafiltration water treatment products

Application design of Haiwell S16S2R series PLC in testing the quality of ultrafiltration water treatment products

Four: HMI screen

1: Operation screen

Application design of Haiwell S16S2R series PLC in testing the quality of ultrafiltration water treatment products

Used for pressure display, used for the setting of charging time, holding time, and holding pressure.

2: 1# station operation

First, connect the gas circuit of the equipment to be inspected, and set the charging time value, holding pressure time value, and holding pressure value. Press the "1# station start" button, 1# station is charged with the charging time setting value, and the text "1# station charging state!" is displayed during charging, 1# station charging solenoid valve Turn on, the 1# station indicator on the test bench will indicate red; when the charging time setting value is reached, the text "1# station charging status!" disappears, 1# station charging solenoid valve is closed, 1# The station enters the pressure holding stage; when the holding pressure time value is reached and the pressure display value is higher than or equal to the holding pressure setting value, the text "1# station pressure is normal!" is displayed, and the 1# station indicator light on the test bench is green Indication; when the holding pressure time value is reached and the pressure display value is lower than the holding pressure setting value, the text "1# station pressure failure!" is displayed, and the 1# station buzzer on the test bench will sound. After the test is completed, press the "1# station stop" button to end the test.

3: 2# station operation

First, connect the gas circuit of the equipment to be inspected, and set the charging time value, holding pressure time value, and holding pressure value. Press the "2# station start" button, 2# station is charged with the set value of the charging time, and the text "2# station charging state!" is displayed during charging, 2# station charging solenoid valve Turn on, the 2# station indicator on the test bench will indicate red; when the charging time setting value is reached, the text "2# station charging status!" disappears, 2# station charging solenoid valve is closed, 2# The station enters the pressure holding stage; when the holding pressure time value is reached and the pressure display value is higher than or equal to the holding pressure setting value, the text "2# station pressure is normal!" is displayed, and the 2# station indicator light on the test bench is green Indication; when the holding pressure time value is reached and the pressure display value is lower than the holding pressure setting value, the text "2# station pressure failure!" is displayed, and the 2# station buzzer on the test bench will sound. After the test is completed, press the "2# station stop" button to end the test.

4: return

Click the "Back" button to return to the startup screen.

Five: Haiwell PLC use experience

Haiwell PLC's analog programming is particularly easy to use, and debugging is also convenient. It is consistent with the design idea, and there is no problem.

Haiwell's 485 communication is also very good, and the real-time and quality of communication with HMI are very good!

Support Haiwell PLC as always!

Matte Film

The anti-glare technology used in the Matte Protective Film can reduce glare to eliminate eye fatigue, and make it easier to watch under direct light, which is more friendly to your eyes.

In order to let you enjoy it for a long time, the Frosted Screen Protector uses durable military-grade TPU material, which has strong durability and scratch resistance. It protects the screen from unnecessary scratches.

It has good anti-fingerprint ability, sweat will not remain on the screen surface, and it is easy to clean without affecting touch sensitivity or response speed.

The adhesive layer ensures that you stick the Protective Film in a stress-free manner and maintain a strong adhesion without leaving any sticky residue.

If you want to know more about Matte Screen Protector products, please click the product details to view the parameters, models, pictures, prices and other information about Matte Screen Protector.

Whether you are a group or an individual, we will try our best to provide you with accurate and comprehensive information about the Matte Screen Protector!


Matte Screen Protector, Frosted Screen Protector, Matt Screen Protector, Matte Hydrogel Film, Matt Protective Film, Anti-Glare Screen Protector

Shenzhen Jianjiantong Technology Co., Ltd. , https://www.jjthydrogelprotector.com

Posted on